Oil/Water Calculator

A guide to help you size your compressor installation with the correct SEPURA™ oil-water separator.

The total free air displacement capacity of the compressor system in cfm, m3/h or ls.

This is a required field

Average Ambient Temperature in °C.

Please enter a value between -70°C and 70°C

The pressure dew-point of the compressed air when a refrigerant air dryer is installed in the system is usually around 3°C. If no refrigerant dryer is installed then this figure should be around 5°C higher than the ambient temperature figure.

Please enter a value between -70°C and 70°C

Enter the average relative Humidity in %.

This is a required field

If you know the ppm/oil water then choose the 'Oil Loading Factor' that reflects this figure. (you will have to press Calculate) Otherwise this figure is subjective. For Example insert a number '2' for a very new and lightly used compressor and up to 6 for a very well used compressor.

This is a required field

Working air pressure of the compressed-air system in bar (g).

This is a required field

Your results

Recommended Sepura Separator
Based on Condensate Flow Sepura 2500
Based on Oil Loading (4000 Hours) Sepura 3500
If the recommendations above are different please choose the largest separator
Result Value
Condensate Flow l/h 33.11
Condensate Total in 4000 hours 132456.61
Oil / h (ml) 10.00
ppm oil / water 301.99
Oil Total 8000 hours (Litres) 80.00
Oil Total 7000 hours (Litres) 70.00
Oil Total 6000 hours (Litres) 60.00
Oil Total 5000 hours (Litres) 50.00
Oil Total 4000 hours (Litres) 40.00
Oil Total 3000 hours (Litres) 30.00
Oil Total 2000 hours (Litres) 20.00
Oil Total 1000 hours (Litres) 10.00